上海益同儀器儀表有限公司
參 考 價(jià) | 面議 |
產(chǎn)品型號
品 牌
廠商性質(zhì)經(jīng)銷商
所 在 地上海
聯(lián)系方式:胡新建查看聯(lián)系方式
更新時(shí)間:2025-06-22 10:05:05瀏覽次數(shù):28次
聯(lián)系我時(shí),請告知來自 儀表網(wǎng)江森CO-T1 CO傳感器Most building codes require a very high ventilation rate in enclosed parking or areas involving vehicle repairs and operation. This must be provided during all hours of use.
江森CO-T1 CO傳感器 Most building codes require a very high ventilation rate in enclosed parking or areas involving vehicle repairs and operation. This must be provided during all hours of use. Most codes allow fans to be operated intermittently as long as carbon monoxide (CO) level does not excE+Ed 25 or 50ppm (check local code). A CO sensor can reduce fan energy costs by switching off or reducing ventilation when CO level is low. The CO-T1 is a CO sensor/transmitter designed specifically for these applications. It delivers all the advantages of electrochemical sensing in a durable, long life (5-year) package and at attractive low price. The loop powered sensor delivers a linear 4~20mA output that is easily integrated into any building control, ventilation or alarm system. FEATURES ? Using carbon monoxide electrochemical cell, the CO-T1 offers fast and reliable measurements over a long period of time; ? Measurement range: 0 - 100 ppm CO ? Two-wire 4-20mA linear output signal corresponding to the measurement range ? Long sensor life, up to 5 years ? non-frill design; cost-optimized and loop powered for direct connection to DDCs ? Easy sensor head replacement minimizes long term operating costs ? Optional measurement range (0 ~ 200ppm or 0 ~ 400ppm) ? Optional terminals for temperature sensing elements such as PT100, PT1000 or NTC 10K. ? Optional duct mount (-IP65) housing SPECIFICATIONS General Sensing Method: Electrochemical Sensor Rated Life: 5 years Temp Operating Conditions: 0 to 50 oC Humidity Operating Conditions: 0 to 90 %RH Storage Conditions: -40 to 70 oC Performance CO Measurement Range: 0 to 100ppm Repeatability: +/-5% of measured value Linearity: +/-5% of measured value Recommended Calibration: 12 months Response Time: T90 =< 60 seconds Warm Up time: less than 2 minutes Power Input: 18 ~ 30 VDC Power consumption: 20mA Outputs Adjustment: Span Output signal: 4 ~ 20mA Terminal Wire Size: 16 ~ 22 AWG
您感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN
中國臺(tái)灣衡欣數(shù)顯溶氧計(jì)AZ8402/AZ-8402
AZ8402/AZ-8402 面議儀表網(wǎng) 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ?
請輸入賬號
請輸入密碼
請輸驗(yàn)證碼
請輸入你感興趣的產(chǎn)品
請簡單描述您的需求
請選擇省份
聯(lián)系方式
上海益同儀器儀表有限公司